Test principle:The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Galactose-1-Phosphate Uridylyltransferase(GALT). Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Galactose-1-Phosphate Uridylyltransferase(GALT). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Galactose-1-Phosphate Uridylyltransferase(GALT), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Galactose-1-Phosphate Uridylyltransferase(GALT) in the samples is then determined by comparing the OD of the samples to the standard curve.
仕様
サイズ:96T
Alternative Names:UDP-glucose--hexose-1-phosphate uridylyltransferase
Species:Human
Assay Type:Sandwich
Sensitivity:11.5 pg/mL
Standard:2000 pg/mL
Detection range:31.25-2000 pg/mL
Sample type:Tissue homogenates, cell Lysates and other biological fluids.