For quantitative detection of RF-IgG in serum, plasma, tissue homogenates and other biological fluids.
Sensitivity:1.875IU/ml
Detection Range:3.125-200IU/ml
Specificity:This assay has high sensitivity and excellent specificity for detection of mouse RF-IgG. No significant cross-reactivity or interference between RF-IgG and analogues was observed.
Precision:Intra-Assay: CV<8%Inter-Assay: CV<10%
Test Principle:This ELISA kit employs the Indirect enzyme-linked immune-sorbent assay technology. Mouse IgG was pre-coated onto 96-well plates. The biotin conjugated anti- RF-IgG antibody was used as detection antibodies. The standards, test samples and biotin conjugated detection antibody were added to the wells subsequently, and washed with wash buffer. HRP-Streptavidin was added and unbound conjugates were washed away with wash buffer. TMB substrates were used to visualize HRP enzymatic reaction. TMB was catalyzed by HRP to produce a blue color product that changed into yellow after adding acidic stop solution. The density of yellow is proportional to the RF-IgG amount of sample captured in plate. Read the O.D. absorbance at 450nm in a microplate reader, and then the concentration of RF-IgG can be calculated.
Storage and Stability:Store unopened kit at 4ºC; store at -20ºC once opened. Store unopened standard at 4°C; once reconstituted, store at 4°C for up to 12 hours or at -20°C for up to 48 hours. Store other components at 4°C. Kit is stable for 6 months after receipt. For maximum recovery of product, centrifuge the original vials after thawing and prior to removing the cap.